rus eng

Application

Contact person
Email
Phone
Company(not necessary)
Comment
Apply

Course registration

Course
Training dates
Number of trainees(not necessary)
Contact person
Phone
Email
Company(not necessary)
Comment(not necessary)
Register

Quick contacts

OILTEAM

Phone

+7 (3822) 660130
+7 (3822) 900307

Email

oilteam@tomsk.oilteam.ru

Адреса

Management Company:
Tomsk, 3 Televisionniy Lane,
Service division:
Tomsk, 3 Razvitiya
Fluid lab:
Tomsk, 8 Razvitiya

Phone

+7(347) 2629899,
+7 (862) 2-255-447

Email

oilteam@oilteam.ru

Адреса

g.Ufa, Kommunisticeskaa 116,
g. Soci, pr. Kurortnyj, 92/5

Phone

+7 (3822) 66-01-30

Email

oilteam@tomsk.oilteam.ru

Адреса

g. Tomsk, pr. Razvitia, 3

Phone

+7 (3822) 66-01-30

Email

oilteam@tomsk.oilteam.ru

Адреса

g. Tomsk, pr. Razvitia, 8

Phone

+7 (3476) 12-65-18

Email

oilteammash@oilteammash.com

Адреса

g. Kumertau, selo Maacnyj, ul. Zeleznodoroznaa, d. 3 kor. 2

Phone

+7 (862) 2-255-447

Email

oilteam@oilteam.ru

Адреса

g. Soci, pr. Kurortnyj, 92/5

Phone

77777

Email

Другие направления

Адреса

Drugie napravlenia

View all contacts
Apply ТУТ ДОЛЖЕН БЫТЬ НУЖНЫЙ ПУНКТ

Equipment

Mobile separation and truck loading system

Basic info

Extended well testing and early production Preliminary treatment of produced fluids, metering, storage, loading or export pumping Gas utilization for power generation

Mobile separation and truck loading system

Purpose and advantages:

  • Extended well testing and early production
  • Preliminary treatment, metering, storage, loading or pumping
  • Gas utilization for power generation

Equipment configuration:

  1. Manifold module (1)
  2. Two-phase or three-phase separator (2)
  3. Storage tank module (3)
  4. Pump module (4) or truck loading station (5)
  5. Horizontal or vertical flare unit (6)
  6. Gas power plant and stand-by diesel generator (7)
  7. Operator room (8)
  8. Instrumentation and controls
  9. Piping and cable connections
Flow rate, bpd up to 3000-6000 (and more)
Gas flow rate, Sm³/d up to 250 000 (and more)
Measurement accuracy of mass flow rate accuracy of measuring ± 2,5% mass.
Measurement accuracy of volumetric gas discharge measuring accuracy ± 5%
Input pressure (design), bar 16; 25; 40; 63; 100; 160
Ambient temperature, ⁰С from -60 to + 50